MAINTAINING YOUR HUMIDIFIER
A regular maintenance program prolongs the life of your humidifier and provides a 
more comfortable home. The frequency of cleaning will depend on the condition of 
your water. 
You can use either hard or soft water in your humidifier, but hard water mineral 
deposits are more difficult to clean than soft water deposits.
Cleaning Humidifier 
(Every 1 to 3 Months Depending on Water Quality)
CAUTION
Voltage Hazard.
Can cause electrical shock 
and equipment damage.
Disconnect power and shut off water supply before installing or servicing.
IMPORTANT
Never oil any part of the humidifier.
Use the following steps to clean your Honeywell humidifier:
1. Disconnect the power and turn off the humidifier water supply.
2. Remove the humidifier cover by lifting the bottom of the cover upward.
3. Lift up the drum shaft from the bearing end and slide it out of the motor coupling 
to remove the drum assembly. See Fig. 1.
NOTE: You will encounter some resistance when removing the drum shaft until you 
hear an audible click.
4. Remove the drum from the assembly.