UC100C ULTRAVIOLET AIR TREATMENT SYSTEM REPLACEMENT LAMP
$XWRPDWLRQDQG&RQWURO6ROXWLRQV
+RQH\ZHOO
+RQH\ZHOO/LPLWHG+RQH\ZHOO/LPLWpH
'RXJODV'ULYH1RUWK
'\QDPLF'ULYH
*ROGHQ9DOOH\01
6FDUERURXJK2QWDULR
09=
Printed in U.S.A. on recycled 
paper containing at least 10% 
post-consumer paper fibers.
MERCURY NOTICE
This device contains mercury in the sealed ultraviolet 
lamp(s). Do not place your used lamp(s) in the trash. 
Dispose of properly.
Broken Lamp Cleanup.
Do not use a household vacuum.
Sweep debris into a plastic bag and dispose of 
properly.
Contact your local waste management authority for 
instructions regarding recycling and the proper 
disposal of old lamp(s). 
Replacing Your Lamps (Annually)
Annual replacement of your lamps is required. To replace your 
lamps:
1. Obtain the correct replacement lamp for your unit. See 
Table 1.
2. Disconnect the power to your HVAC system.
3. Open the enclosure door.
4. Disconnect the lamp cable from the electrical subpanel. 
Allow the lamp to cool for at least 15 minutes.
5. Rotate the lamp knob until the tabs align with the slots; 
then carefully remove the lamp; be careful not to strike 
or hit the lamp glass on the enclosure edges.
6. Carefully insert the new lamp assembly into the     
enclosure. Avoid striking the lamp glass against the hole 
edges or other object to prevent damage or breakage. If 
necessary, use a clean, dry cloth to help guide the lamp 
assembly during installation. Do not touch the lamp   
surface with your hands; use only a soft cloth.
7. Align the tabs on the lamp knob with the slots in the 
lamp receptacles and turn lamp clockwise until it stops.
8. Connect the lamp assembly cord conector to the mating 
receptacle located on the exterior of the electrical     
sub-compartment.
9. Verify that the connector is fully inserted into the    
receptacle.
WARNING
UV Light Hazard. 
Harmful to bare skin and eyes. 
Can cause temporary or permanent loss of vision.
Never look at the lamps while illuminated.
Only view illumination by way of the light indicator 
located on the lamp knob.
10. Reconnect the power to the HVAC system.
11. Verify that your ultraviolet lamp(s) are operating only by 
viewing through the lamp light indicator on the lamp 
knob. Never look directly at your lamp(s) while 
illuminated
.
Table 1.  Replacing Your Lamp(s).
Unit Description
Replacement Lamps
Wattage
UV100C3002 Ultraviolet Air Treatment System (Light 
Commercial model)
UC100C3007
36W