Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Rapid
42
Semi-rapid
32
Auxiliary
28
Other technical data
TOTAL POWER:
Gas original:
G20 (2H) 20 mbar = 7,7 kW
Gas replacement:
G30 (3+) 28-30 mbar = 545 g/h
G31 (3+) 37 mbar = 536 g/h
Electric supply:
220-240 V ~ 50/60 Hz
Appliance category:
II2H3+
 
Gas connection:
G 1/2"
 
Appliance class:
3
 
Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER kW
MINIMUM POWER kW
INJECTOR MARK
1/100 mm
Rapid
2,9
0,75
119
Semi-rapid
1,9
0,45
96
Auxiliary
1,0
0,33
70
Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid
2,7
0,75
86
196
193
Semi-rapid
1,9
0,45
71
138
136
Auxiliary
1,0
0,33
50
73
71
Energy efficiency
Product information according to EU 66/2014
Model identification
 
ZGO63414BA
14