Cisco Cisco TelePresence Video Communication Server Expressway

다운로드
페이지 76
Create a new cluster of VCS X6.0 peers 
Cisco VCS Deployment Guide: Cluster creation and maintenance (Cisco VCS X6) 
Page 24 of 76 
 
 
Create a new cluster of VCS X6.0 peers 
This process creates a cluster of a single Cisco VCS.  
To complete the cluster containing multiple Cisco VCSs, once this section is complete, follow the 
instructions in “Add an X6.0 VCS to a VCS X6.0 cluster” to add the non-master peers to the cluster. 
Do not use this process if the cluster already exists; instead, follow the instructions in “Add an X6.0 
VCS to a VCS X6.0 cluster”.
 
Note: If Device Provisioning or FindMe is to be used with an X6.0 VCS cluster, then use of Cisco 
TMS is essential. If neither Device Provisioning nor FindMe is to be used, then use of Cisco TMS is 
optional but recommended. 
If Cisco TMS is to be used with this Cisco VCS cluster, ensure that it is running version 12.6 or later. 
Prerequisites 
 
all Cisco VCSs to be included in the cluster must all be running the same version of Cisco VCS 
software, and that version of software must be X6.0 
 
if Device Provisioning and FindMe are configured, they must have already been proven to be 
operational on the master Cisco VCS after its upgrade to X6.0 
Set up the master peer of the cluster 
This process sets up the first (Master) peer of this new cluster – additional peers are added afterwards 
using the “Add an X6.0 VCS to a VCS X6.0 cluster” process. 
1.  Determine which Cisco VCS will be the Master. 
Note
 
The Master Cisco VCS will be the source of the configuration information for all Cisco VCS peers 
in the cluster. Non-master Cisco VCS peers will have their configuration deleted and replaced by 
that from the Master. 
 
FindMe information can only be kept if the relevant Cisco VCS is already configured to operate 
with Cisco TMS and is configured with Enable TMS Agent Data Replication. (FindMe information 
is deleted and overwritten by the information from Cisco TMS when Enable TMS Agent Data 
Replication is first enabled.) 
On neighbor Gatekeepers (GKs) and Border Controllers (BCs): 
2.  If the Master Cisco VCS has a traversal zone configured to connect with any GK or BC, upgrade 
these systems to N6.1 or Q6.1 or later code. 
For the Master Cisco VCS: 
3.  Check that no other Cisco VCS (anywhere) has this Cisco VCS’s IP addresses in their Alternates 
or Clustering Peers list. 
4.  Check that the Cisco VCS is running X6.0 software. 
5.  Backup the Cisco VCS (See Appendix 1 for details). 
6.  On the web interface of this Master Cisco VCS, review the configuration to ensure that the Cisco 
VCS has: 
• 
A valid Ethernet speed (System > Ethernet). 
• 
Valid IP address and IP gateway (System > IP).