Changes to the Release Notes
Changes to the Release Notes
This section documents supplemental changes that have been added to the Release Notes for Cisco ONS 
15454 SDH Release 4.6.6 
since the production of the Cisco ONS 15454 SDH System Software CD for 
Release 4.6.6.
The following changes have been added to the release notes for Release 4.6.6
Changes to Caveats
The following caveat has been added to the release notes.
Caveats
Review the notes listed below before deploying the ONS 15454 SDH. Caveats with DDTS tracking 
numbers are known system limitations that are scheduled to be addressed in a subsequent release. 
Caveats without DDTS tracking numbers are provided to point out procedural or situational 
considerations when deploying the product.
Hardware
STM1E-12 Card Support
The STM1E-12 card is not supported in this release. This card will be supported in a future release. 
Caveats herein pertaining to this card also do not apply.
CSCdw92634 
SDH DS3-i and E3 electrical cards only support a VC4 J1 trace string setting for all VC4s together. You 
cannot set the J1 byte for individual VC4s. This issue is a limitation of hardware.    