Cisco Cisco UCS B440 M1 High-Performance Blade Server 문제 해결 가이드
Contents
Introduction
Prerequisites
Requirements
Components Used
Background
Discovery Problems
Discovery Fails at 3% - Firmware Mismatch
Solution
Discovery Fails at 7% - CPU Mismatch
Solution
Introduction
This document describes two possible discovery failures that can occur when a B460 M4 motherboard is replaced and their respective solutions.
Prerequisites
Requirements
This document assumes knowledge of UCS B460 M4 and UCS Manager (UCSM).
Components Used
B460 M4 Blade Server
●
UCS Manager
●
Firmware 2.2(3b)
●
Background
The B460 M4 server consists of two Scalable M4 Blade Modules (B260 M4) and a Scalability Connector that cross-connects the two Blade Modules and
allows them to function as a single server. The Blade Module on the bottom is the “Master” and the Blade Module on the top is the “Slave.”
allows them to function as a single server. The Blade Module on the bottom is the “Master” and the Blade Module on the top is the “Slave.”