327 
 
Warning 
Message 
Type 
Message 
Cause/Remedy 
Description 
ID 
CI Status 
Set 
Different  CA 
Systems  in 
Top/Bottom 
Slots 
 
Cause: Different  CA 
systems  are used  in the 
slots. 
Remedy: Replace  the CA 
cards  to  use the same 
CA system. 
 
Different  CA Systems 
in Top/Bottom  slots. 
42500 
CI Status 
Clear  
OK 
– 
– 
42500 
Video  Format 
Mismatch 
Set 
Video  format 
mismatch 
– 
Video  Format 
Mismatch. 
43000 
Video  Format 
Mismatch 
Clear 
Video  format 
match 
– 
– 
43000 
Temperature 
Warning 
Set 
Temperature 
over Warning 
threshold 
Cause: Room 
temperature  too  high, or 
air flow  is blocked. 
Remedy: Check 
openings  on front  and 
rear panels  for blockage. 
Lower  the room 
temperature  or improve 
air flow  to  the device.   
Temperature  is  above 
normal  operating 
range. 
44000 
Temperature 
Warning 
Clear 
Temperature 
normal 
– 
Temperature  is  within 
the normal  operating 
range. 
44000 
FPGA 
Temperature 
Warning 
Set 
Temperature 
over Warning 
threshold 
Cause: Room 
temperature  is too  high, 
or air flow  is blocked.    
Remedy: Check  the 
openings  on front  and 
rear panels  for blockage. 
Lower  the room 
temperature  or improve 
air flow  to  the device. 
FPGA temperature  is 
above normal 
operating  range. 
45000 
FPGA 
Temperature 
Warning 
Clear 
Temperature 
normal 
– 
FPGA temperature  is 
within  the normal 
operating  range. 
45000 
VBI  Data 
Set 
2nd VBI  PID 
attempt  to  write 
same line 
Cause: Uplink 
configuration  issue. 
Remedy: Contact  uplink 
to  verify expected  VBI 
settings. 
Conflicting  VBI  data 
on second  VBI  PID. 
49000