Cisco Cisco Web Security Appliance S170 사용자 가이드
2-10
Cisco IronPort AsyncOS 7.5.7 for Web User Guide
Chapter 2 Using the Web Security Appliance
Committing and Clearing Changes
Committing Changes
To commit changes made in the web interface:
Step 1
Click the Commit Changes button.
The Uncommitted Changes page appears.
Step 2
Enter comments in the Comment field if you choose.
Step 3
Click Commit Changes.
Clearing Changes
To clear changes made in the web interface:
Step 1
Click the Commit Changes button.
The Uncommitted Changes page appears.
Step 2
Click Abandon Changes.
Committing and Clearing Changes in the CLI
Commit changes using the
commit
command. Most configuration changes you make in the Command
Line Interface (CLI) are not effective until you issue the
commit
command. You may include comments
up to 255 characters. Changes are not verified as committed until you receive confirmation along with a
timestamp. The
timestamp. The
commit
command applies configuration changes made to appliance since the last
commit
or
clear
command issued.
For more information about using the
commit
command, see
.
Clear changes using the
clear
command. For more information about using the
clear
command, see
.
Checking for Web Proxy Restart on Commit
Some configuration changes you make to the Web Security appliance trigger a Web Proxy restart when
you commit the changes. When the Web Proxy restarts, the Web Security appliance allows web traffic
to continue but there is a brief interruption of Web Proxy services, such as anti-malware scanning.
Typically, the Web Proxy uses less than 30 seconds to restart due to a configuration change. (If the Web
Proxy restarts due to an internal error, the entire restart process may take a few minutes to start all
services on the appliance.)
you commit the changes. When the Web Proxy restarts, the Web Security appliance allows web traffic
to continue but there is a brief interruption of Web Proxy services, such as anti-malware scanning.
Typically, the Web Proxy uses less than 30 seconds to restart due to a configuration change. (If the Web
Proxy restarts due to an internal error, the entire restart process may take a few minutes to start all
services on the appliance.)