cannot be performed
In below cases, hot replacement of the failed HDD or SSD cannot be performed.
-
Case where multiple deadlock occurs
Multiple deadlock occurs when more than one hard disk fail to be recognized at the same time.
Multiple deadlock occurs when more than one hard disk fail to be recognized at the same time.
-
The HDD or SSD is RAID0 configuration and it is not mirror configuration by software.
If a HDD or SSD fails in this case, it is required to reconfigure the Hardware RAID after replacing HDD or
SSD. Recover from back up data because data in failed HDD or SSD is not guaranteed.
If a HDD or SSD fails in this case, it is required to reconfigure the Hardware RAID after replacing HDD or
SSD. Recover from back up data because data in failed HDD or SSD is not guaranteed.
When replacing the HDD or SSD, it has to be done with the system power off. The workflow is described
below.
Remarks
Step2 is performed by the field engineer in charge of your system.
below.
Remarks
Step2 is performed by the field engineer in charge of your system.
1. Turn off the power to the system.
2. Replace the HDD or SSD.
3. Restart the system
In C880 M4 server (E7-8800 v3 CPU), start HII Confguration Utility from Boot Manager front page.
In C880 M4 server (E7-8800 v2 CPU), start WebBIOS from the Boot Manager front page.
In C880 M4 server (E7-8800 v2 CPU), start WebBIOS from the Boot Manager front page.
4. Create the array configuration
In C880 M4 server (E7-8800 v3 CPU), create the array configuration with HII Configuration Utility.
In C880 M4 server (E7-8800 v2 CPU), create the array configuration with WebBIOS.
In C880 M4 server (E7-8800 v2 CPU), create the array configuration with WebBIOS.
5. Restore the data for backup.