D9824 Alarm Messages 
The status of the D9824 receiver and its immediate surroundings is reported to the 
front panel in the form of messages and alarms. You can enable or disable messages 
in the Alarm/Warning settings. 
The following table shows an alphabetical list of the available messages and their 
default alarm status. The Set Messages and Clear Messages are displayed in the 
Warning History when the messages are set or cleared respectively. 
Only alarm conditions can be used to trigger rear panel relays to control external 
alarm equipment. Warnings are not associated with relay operation. 
 
Alarms 
Alarm 
Message 
Type 
Message 
Cause/Remedy 
Description 
Severity 
PSB non-
compliant 
Set 
PROD incomplete 
or PSB non-
compliant 
Cause: Production 
command 
exit_weak_state 
was not issued 
after production 
programming was 
completed. 
Remedy: The 
Exit_weak_state 
command should 
be issued by the 
user with PROD 
credentials if the 
device has not yet 
been shipped to 
the customer. 
Otherwise, the 
customer must 
reset credentials 
using the Front 
Panel. 
Device is in the 
WEAK state 
after 
production 
programming 
is complete. 
Major 
PSB non-
compliant 
Clear 
PSB compliant