Cisco Cisco TelePresence Video Communication Server Expressway

다운로드
페이지 76
Enabling Microsoft Edge Server and VCS TURN 
capabilities
Ensure that the Microsoft Interoperability option key has been installed on the “Lync gateway” VCS.
To enable call connectivity with Lync clients calling via an Edge server, the B2BUA needs to have TURN 
services properly configured to point to a VCS Expressway with TURN enabled.
 1.  Go to 
Applications > B2BUA > B2BUA TURN servers
.
 2.  Click New.
 3.  Configure the fields as follows:
TURN server address
IP address of a VCS Expressway which has TURN enabled.
(Just a single VCS; it may be just one peer from a cluster.)
TURN server port
3478
The port on the VCS Expressway that is listening for TURN requests.
On Large VM server deployments you can configure a range of TURN 
request listening ports. The default range is 3478 – 3483.
Description
An optional description of this TURN server.
TURN services username 
and
TURN services password
The username and password to access the TURN server.
 4.  Click Add address.
 5.  Repeat the above steps if additional TURN servers are required.
 6.  Go to 
Applications > B2BUA > Microsoft Lync > Configuration
.
 7.  Configure the fields as follows:
Offer TURN Services
Yes
 8.  Click Save.
Microsoft Lync and Cisco VCS Deployment Guide (X8.1)
Page 42 of 76