Known limitations 
Cisco TelePresence Video Communication Server X7.0.1 Software Release Notes 
Page 20 of 29 
 
 
Known limitations 
 
 
 
Manufacturer 
Equipment / Version / Protocol 
Summary 
Polycom 
HDX 9000 / 3.0.0.2 and 3.0.2 / 
SIP 
An H.323 call routed via Cisco VCS will not connect when 
the destination is Polycom HDX registering using SIP. 
Polycom HDX does not send response to Cisco VCS 
interworked SIP INVITE request. 
Polycom 
VSX 7000 / 9.0.6.1 / SIP 
A SIP call routed via the Cisco VCS to a Cisco 
TelePresence System Integrator C Series (using H.323) 
will connect, however the call will be disconnected when 
the VSX attempts to refresh the session. 
VSX attempts to refresh session using an UPDATE 
request, which is not supported by Cisco VCS. 
Polycom 
VSX 7000 / 9.0.6.1 / H.323 
An H.323 call routed via the Cisco VCS will connect when 
the destination is Cisco IP Video Phone E20 (using SIP), 
however no video will be seen on the E20. 
Polycom VSX does not open the media channel that is 
signalled during call set up. 
Lifesize 
Room / 4.6.0 / SIP 
An H.323 call routed via Cisco VCS will be disconnected 
when the H.323 party puts the call on-hold. 
Lifesize Room (SIP) incorrectly responds to Cisco SDP 
(media capability) offer.  
This issue is resolved in Lifesize Room version 4.8.3. 
Lifesize 
Room / 4.6.0 / SIP 
A Movi SIP call routed via Cisco VCS will connect, 
however no video will be seen on the Lifesize Room. 
Lifesize Room (SIP) incorrectly responds to Cisco SDP 
(media capability) offer. 
This issue is resolved in Lifesize Room version 4.8.3. 
Lifesize 
Room / 4.6.0 / H.323 
A C20 or E20 SIP call routed via Cisco VCS will connect, 
however no video will be seen on the Lifesize Room. 
C20 and E20 do not send media to Lifesize after call is 
connected. 
Tthis issue is resolved in Lifesize Room version 4.8.3. 
Lifesize 
Room / 4.6.0 and 4.8.3 / H.323 
A Movi SIP call routed via Cisco VCS will connect, 
however no video will be seen on the LifeSize Room 
system if an HD camera is used and the requested 
bandwidth is > 1MBps.