Cisco Cisco Web Security Appliance S170 릴리즈 노트

다운로드
페이지 76
C I S C O   I R O N P O R T   A S Y N C O S   6 . 3 . 8   F O R   W E B   R E L E A S E   N O T E S
 
57
Workaround: Use the 
smtprelay
 CLI command to configure an SMTP relay host. [Defect ID: 
51811] 
Deleting directories on the appliance causes errors when saving or loading a 
configuration file or when upgrading AsyncOS for Web
Errors occur under the following circumstances:
• An administrator connects to the Web Security appliance using FTP and deletes some 
directories, such as directories that exist for holding log files.
• The configuration is saved or loaded, or AsyncOS for Web is upgraded.
Workaround: Recreate all missing directories on the appliance before saving or loading the 
configuration file and before upgrading AsyncOS for Web. [Defect ID: 51514] 
Web Proxy erroneously adds its domain name as a DNS search domain in some cases
When a client explicitly forwards a request for a URL that does not exist, the Web Proxy 
appends its own name domain to the URL and tries the DNS lookup again. For example, the 
Web Security appliance host name is wsa.example.com, and a client sends a request to 
 
http://myhost.mysite. The original DNS lookup fails to find http://myhost.mysite, so the Web 
Proxy tries another DNS lookup for http://myhost.mysite.example.com.
Workaround: Configure the appliance to use transparent mode and transparently redirect 
client requests to the Web Proxy. [Defect ID: 51864] 
Changing the name of the Web Security appliance host name does not take effect 
immediately
Changing the name of the Web Security appliance host name does not take effect 
immediately. 
Workaround: Restart AsyncOS for Web, or contact Customer Support to restart the Web Proxy 
only. [Defect ID: 51933] 
Changing the default gateway does not display the new IP address in the web interface 
immediately
When you change the default gateway and click Submit, the Network > Routes page does not 
immediately display the new IP address for the default gateway after clicking Submit.
Workaround: Reload the page in the browser and the correct default gateway address 
appears. [Defect ID: 52022] 
Cannot enter text in some Identity fields using Safari 4.0.x
When you use the Safari browser version 4.0.x to access the web interface, you cannot enter 
text in the Description or Define Members by Subnet fields for Identity groups under the 
following circumstances: