Cisco Cisco 10 Gigabit Modules 백서

다운로드
페이지 7
 
 
© 2005 Cisco Systems, Inc. All rights reserved. 
Important notices, privacy statements, and trademarks of Cisco Systems, Inc. can be found on cisco.com. 
Page 5 of 7 
 
 
To measure Er a digital oscilloscope is required. Er is part of a variety of eye diagram measurements performed by the oscilloscope (Figure 1). 
Figure 1.  Typical Oscilloscope Eye Diagram Measurement and P1, P0 
 
For a more detailed treatment of Er and OMA, see: 
http://pdfserv.maxim-ic.com/en/an/3hfan222.pdf
 
About the Authors 
Wael William Diab 
Technical Leader, Cisco Systems 
Secretary, IEEE 802.3 CSMA/CD Working Group (Ethernet) Chief Editor, IEEE 802.3ah (Ethernet in the First Mile) 
Piers Dawe 
Agilent Technologies 
Vice-Chair, Optics Sub Task Force, IEEE 802.3ah (Ethernet in the First Mile) 
Alessandro Barbieri 
Product Manager, Ethernet Systems Group, Cisco Systems