To measure Er a digital oscilloscope is required. Er is part of a variety of eye diagram measurements performed by the oscilloscope (Figure 1).
Figure 1. Typical Oscilloscope Eye Diagram Measurement and P1, P0
For a more detailed treatment of Er and OMA, see:
http://pdfserv.maxim-ic.com/en/an/3hfan222.pdf
About the Authors
Wael William Diab
Technical Leader, Cisco Systems
Secretary, IEEE 802.3 CSMA/CD Working Group (Ethernet) Chief Editor, IEEE 802.3ah (Ethernet in the First Mile)
Piers Dawe
Agilent Technologies
Vice-Chair, Optics Sub Task Force, IEEE 802.3ah (Ethernet in the First Mile)
Alessandro Barbieri
Product Manager, Ethernet Systems Group, Cisco Systems