Cisco Cisco Agent Desktop 8.5 기술 참조

다운로드
페이지 288
Cisco CAD Service Information
260
May 2007
ones used in the CAD-BE URL. If changes are made to the 
settings in CAD Configuration Setup, the BIPPA Service(s) must 
be restarted for the changes to take effect. 
Make sure port 59012 is not blocked from the client or server 
computer. 
On a nonredundant system, if the LRM Service is down, then the 
BIPPA Service will become standby. Restart the LRM Service.
The BIPPA Service will not become active until the CAD 
Configuration Setup utility has run successfully. Complete all 
windows in the CAD Configuration Setup utility. 
Desktop Administrator, Agent Desktop, or Supervisor Desktop 
was installed on the same computer as the CAD services. They 
clear a registry key (IOR Hostname under Site Setup) required by 
the BIPPA Service. Set the registry to the public IP address of the 
CAD services computer.
Problem
When starting up CAD-BE, the Java Runtime Environment installation 
begins.
Solution
The agent is running CAD-BE on a computer where the Java Runtime 
Environment is not installed. Once JRE is installed, this will not happen 
again. Allow the JRE installation to complete, after which CAD-BE will 
start normally.
Problem
When starting up CAD-BE, the browser displays the following message: 
“This site might require the following ActiveX control 'J2SE Runtime 
Environment 5.0 Update 11' from 'Sun Microsystems, Inc.'. Click here to 
install…”
Solution
The agent is running CAD-BE on a computer where the Java Runtime 
Environment is not installed. The browser's security settings prevent the 
browser from automatically installing the Java Runtime Environment. 
See the Cisco CAD Installation Guide for the correct Internet Explorer 
settings. When the settings are correct, restart CAD-BE.
Problem
When starting up CAD-BE, the browser displays the following message: 
“Your security settings do not allow Web sites to use ActiveX controls