Avocent GXT3-1500RT120 사용자 설명서

다운로드
페이지 4
3
0.9 Output Power Factor 
Liebert GXT3 rated output power 
factor of 0.9 better matches up with 
switch-mode power supplies used in 
today’s IT equipment.  A higher output 
power factor allows for a more efficient 
utilization of the UPS.
Wide Input Voltage Window 
Prolongs battery life by allowing the 
UPS to maximize the use of utility power 
before transferring to battery when input 
voltage exceeds specified limits.
Power-Factor Correction 
Prevents noise, harmonics and distortion 
from being passed on to connected loads 
or from being fed back to the utility.
Internal Automatic and Manual  
Bypass Capability 
Assures continuity of power to critical 
loads during system problems or 
maintenance. 
Intelligent Battery Management 
Includes efficient three-stage charging 
technique and comprehensive 
discharging protection that extends 
battery life for greater availability.
Input Circuit Breaker  
Provides increased protection to ease 
recovery from overloads.
Lightning and Surge Protection 
The transient voltage surge suppression 
(TVSS) circuitry inside Liebert GXT3 
provides additional protection for the 
connected equipment from incoming 
spikes, surges, and other power 
anomalies present on the incoming  
utility power source.
Intelligent Fan Operation 
Automatically changes rotation speed 
depending on system requirements to 
decrease power consumption and noise.
Efficient Operation 
≥ 88% AC-AC, minimum.
Warranty Protection 
The industry’s best warranty – No-hassle 
two-year warranty with UPS replacement 
in the event of problems. Shipping is 
free for both original UPS return and the 
replacement unit. Optional one-year and 
three-year extensions also available.
Higher Availability:
Advance Early Warning  
of UPS System Status
 
Multiple audible and visual alarms  
immediately alert you to an output 
overload, low battery, bypass, battery 
discharge, battery loss or replace battery 
condition. 
4-8 minutes of Battery  
Backup Time at Full load 
Provides ample time for an orderly 
shutdown of connected equipment when 
utility power fails. Optional matching 
external battery cabinets offer additional 
backup time. 
Overload Capability 
Designed to handle output overload 
conditions.
Full Sequenced Battery Testing 
Provides automatic and manual  
self-diagnostic battery testing 
capabilities. This provides a 
comprehensive analysis of the condition 
of the batteries within the UPS and will 
notify you when the internal batteries 
need to be replaced.
User Replaceable  
Hot Swappable Batteries 
Easy to replace batteries increase product 
life and provide prolonged UPS reliability. 
Batteries are conveniently located behind 
the front bezel of the unit. 
Lowest Total Cost Of Ownership:
Liebert GXT3 contains internal batteries, 
and is also able to support up to four  
external battery cabinets – also 2U size.
Liebert GXT3 mini-tower 
model provides 1000VA 
capacity in a compact 
design.
Liebert MicroPOD
Multiple Choices For  
Communication, Shutdown 
And Reporting:
SNMP And Web-Based 
Communication Options 
Liebert IntelliSlot® Web Card provides 
SNMP and web-based management to 
your Liebert GXT3. Provides SNMP MIB to 
monitor and control your UPS from your 
network management station or any PC 
running Microsoft Internet Explorer.
   
Network shutdown
   
Sends both SNMP traps and emails for 
event notification, and automatically 
emails a daily UPS history
   
Auto-senses 10M/100M Ethernet
   
Compatible with shutdown software 
to ensure graceful computer shutdown
The Liebert GXT3 is also fully  
compatible with:
   
Liebert MultiLink™ shutdown software 
–included with the Liebert GXT3 UPS 
   
Liebert Nform™ monitoring software
   
Liebert Multiport multiplexing unit
   
Liebert Intellislot Relay Interface Card
USB Communications 
Windows (98 and later) built-in  
power management functions provide 
monitoring of UPS status and manage 
the automatic orderly shutdown of the 
computer if a power outage ever exceeds 
the battery capacity of the UPS. Liebert 
MultiLink shutdown software can also be 
used via USB connection.
Optional Liebert MicroPOD  
Output Distribution And  
Maintenance Bypass Module 
When your computer system can’t be 
without power, even for scheduled UPS 
maintenance, the Liebert MicroPOD 
Maintenance Bypass and Output 
Distribution Unit ensures continuous 
uptime. It allows you to manually transfer 
connected equipment to utility power via 
a maintenance bypass switch, permitting 
scheduled service or UPS replacement 
without the need to shut down 
connected equipment. Features include:
   
2U height minimizes rack space 
requirements
   
Installs with plug-and-play ease
   
Two-year, no-hassle replacement 
warranty