534
Caveats for Cisco IOS Release 12.2
OL-3513-16 Rev. G0
Resolved Caveats—Cisco IOS Release 12.2(10); Wide-Area Networking
•
CSCdx23889
Symptoms
Calls may be rejected when a gateway performs overlap sending such as in calls in which
the called party number exceeds 20 digits.
Conditions
This symptom is observed on a gateway when the gateway uses overlap sending. The
gateway rejects the call if a call proceeding message is received without a channel identity (ID) even
though a channel ID has already been received in a setup acknowledgement message and a channel
ID is not required.
though a channel ID has already been received in a setup acknowledgement message and a channel
ID is not required.
Workaround
There is no workaround.
•
CSCin01781
Symptoms
Call waiting does not function when the second call is an external call. It functions
normally when the second call is an internal call.
Conditions
The conditions under which this symptom occurs are not known at this time.
Workaround
There is no workaround.
•
CSCin04769
Symptoms
A universal access sever may reload while it attempts to call another universal access
server.
Conditions
This symptom is observed on a Cisco AS5300 universal access server that is running the
c5300-js-mz.122-2.XB image of Cisco IOS Release 12.2(2)XB. This symptom occurs when the
Cisco AS5300 initiates a V.110 call to a Cisco 5850 universal access server.
Cisco AS5300 initiates a V.110 call to a Cisco 5850 universal access server.
Workaround
There is no workaround.
•
CSCin05568
Symptoms
A router may reload after the shutdown interface configuration command followed by
the no shutdown interface configuration command is entered on an interface.
Conditions
This symptom is observed on an X.25 over an ISDN D-channel interface. This symptom
occurs after the shutdown interface configuration command is entered and when the no shutdown
interface configuration command is entered on the interface after the timer is started. This symptom
occurs only if X.25 is configured on the interface.
interface configuration command is entered on the interface after the timer is started. This symptom
occurs only if X.25 is configured on the interface.
Workaround
There is no workaround.
•
CSCuk30274
Symptoms
A protocol emulate network cannot be configured for the NET 5 switch type.
Conditions
The conditions under which this symptom occurs are not known at this time.
Workaround
There is no workaround.