Cisco Aironet Series Power Injector AIR-PWRINJ1500-2= Installation Instructions
 
  Technical Specifications
Technical Specifications
Input voltage
100 to 240 VAC
231485
Output voltage
56.0 VDC
Voltage range tolerance
54 VDC to 57 VDC
Maximum current
1.43 A
No load current
15 mA
Output 1 voltage and 
current
56VDC@0.71A
 
Pin 3, 6—+56VDC
 
Pin 1, 2—Return
Output 2 voltage and 
current
56VDC@0.71A
 
Pin 4, 5—+56VDC
 
Pin 7, 8—Return
Operating temperature
-40 to 131 degrees F
 
(-40 to 55 degrees C)
Storage temperature
-58 to 185 degrees F
 
(-50 to 85 degrees C)
Operating humidity
10% to 90% 
non-condensing
Storage humidity
10% to 95% 
non-condensing
Length
8 in.(20.3 cm)
Width
4.25 in.(10.8 cm)
Height
2.5 in. (6.3 cm)
Regulatory Information 
The following information is for FCC compliance of Class B devices:
The equipment described in this manual generates and may radiate radio-frequency energy. If it is not 
installed in accordance with Cisco’s installation instructions, it may cause interference with radio and 
television reception. This equipment has been tested and found to comply with the limits for a Class B 
digital device in accordance with the specifications in part 15 of the FCC rules. These specifications are 
designed to provide reasonable protection against such interference in a residential installation. 
However, there is no guarantee that interference will not occur in a particular installation. 
Modifying the equipment without Cisco’s written authorization may result in the equipment no longer 
complying with FCC requirements for Class A or Class B digital devices. In that event, your right to use 
the equipment may be limited by FCC regulations, and you may be required to correct any interference 
to radio or television communications at your own expense.