  Grounding the Power Injector
Step 5
Insert a fastener into the mounting tab holes. Tighten the screw just enough to keep it secure in the wall 
anchor. The fastener must be at least 0.62-in (16 mm) long.
Step 6
Use a screw driver to tighten the screw into the wall anchor.
Grounding the Power Injector
We recommend that you ground the power injector after installing it. Follow these steps to ground the 
power injector.
Note
Use a minimum 12 AWG or 2.5 mm cross-sectional area, 90
o
C, copper, green/yellow conductor for 
permanent ground connection.
Step 1
Attach the wire to a UL listed ring lug, suitable for conductor size. Be sure to double crimp the 
connection.
Step 2
Attach the ring lug to a mounting tab on the power injector.
Step 3
Attach other end of the wire to a permanent ground connection in the building installation.
Installing the Power Injector
Follow these steps to install the power injector:
Step 1
Plug a shielded outdoor rated Ethernet cable into the port on the power injector labeled To AP.
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. 
Statement 1023
Note
To comply with FCC regulations, the length of Ethernet cable connecting the power injector to 
the access point cannot be less than 10 ft (3 m).
Step 2
Plug the other end of the Ethernet cable into the Ethernet Port on the access point.
Note
For detailed information about connecting the Ethernet cable on the access point, see the Cisco 
Aironet 1520 Series Outdoor Mesh Access Point Hardware Installation Guide. 
This guide is 
available at cisco.com.
Step 3
Plug a shielded outdoor rated Ethernet cable into the port labeled To Switch on the power injector.