Warning
Connect the unit only to DC power source that complies with the Safety Extra-Low 
Voltage (SELV) requirements in IEC 60950 based safety standards 
Statement 1033
Internal 6 ampere-hour battery
The access point can be connected to more than one power source. The access point detects available 
input sources and switches to the preferred power source using the following prioritization:
AC or POC power
External DC power
1520 power injector PoE power
Internal battery power
Warning
This unit might have more than one power supply connection. All connections must be 
removed to de-energize the unit. 
Statement 1028
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. 
Statement 1023
Caution
To provide inline PoE, you must use the 1520 series power injector. Other power 
injectors, PoE switches, and 802.3af power sources cannot provide adequate power, 
which may cause the access point to malfunction and cause over-current conditions at the 
power source. You must ensure that the switch port connected to the access point has PoE 
turned off.
Caution
Do not install the power injector and the power outdoors. They must be installed indoors.
Caution
When the access point is installed outdoors or in a wet or damp location, the AC branch 
circuit that is powering the access point should be provided with ground fault protection 
(GFCI), as required by Article 210 of the National Electrical Code (NEC).
Three AC power cord options are available: