Cisco Cisco Aironet 1530i Outdoor Access Point 설치 가이드

다운로드
페이지 40
16
 
Power Injectors
The 1530 Series Access Points support the following power injectors:
AIR-PWRINJ1500-2= — 100-240 VAC input, indoor use only
AIR-PWRINJ-30= — 100-240 VAC input, indoor use only
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. 
Statement 1023
Caution
When the access point is installed outdoors or in a wet or damp location, the AC branch 
circuit that is powering the access point should be provided with ground fault protection 
(GFCI), as required by Article 210 of the National Electrical Code (NEC).
Ethernet (PoE) Ports
The access point supports an Ethernet uplink port (PoE-In). The access point Ethernet uplink port uses 
an RJ-45 connector (with weatherproofing) to link the access point to the 10BASE-T, 100BASE-T or 
1000BASE-T network. The Ethernet cable is used to send and receive Ethernet data and to optionally 
supply inline 56-VDC power from the power injector.
Tip
The access point senses the Ethernet and power signals and automatically switches internal 
circuitry to match the cable connections.
Warning
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. 
Statement 1023
The Ethernet cable must be a shielded outdoor rated Category 5e (CAT5e) or better cable. The access 
point senses the Ethernet and power signals and automatically switches internal circuitry to match the 
cable connections.