Miscellaneous Usage and Configuration Guidelines
Using the Mode Button
Using the Mode button (see 
) you can:
Reset the AP to it’s default factory-shipped configuration.
Clear the AP’s internal storage, including all configuration files and the regulatory domain 
configuration.
To use the mode button, press, and keep pressed, the mode button on the access point during the AP's 
boot cycle. Wait until the AP's status LED changes to Amber. During this, the AP console shows a 
seconds counter, counting the number of seconds the mode button is pressed. Then:
To reset the AP to it’s default factory-shipped configuration, keep the mode button pressed for less 
than 20 seconds. The AP's configuration files are cleared. 
This resets all configuration settings to factory defaults, including passwords, WEP keys, the IP 
address, and the SSID. However, the regulatory domain provisioning is not reset.
To clear the AP’s internal storage, including all configuration files and the regulatory domain 
configuration, keep the mode button pressed for more than 20 seconds, but less than 60 seconds.
The AP's status LED changes from Amber to Red, and all the files in the AP's storage directory 
are cleared. This also removes any regulatory domain provisioning made previously and resets the 
AP back to -UX domain.
If you keep the mode button pressed for more than 60 seconds, the mode button is assumed faulty and 
no changes are made.