Cisco Cisco Aironet 340 Ethernet Bridges 사용자 가이드
13 - 14 Aironet 340 Series Bridge
broadcast message similar to the one below to all other units on the
infrastructure. It reports that it has a new firmware file with its
assigned version number.
infrastructure. It reports that it has a new firmware file with its
assigned version number.
BR105E 004096001d45 has code version 3.2a (checksum
1598)
The remote units then decide whether to respond based on the value
of their rcv_distribute parameter.
of their rcv_distribute parameter.
When the local unit receives a response to its request, the remote
unit is added to a list of units to be loaded. When the response time-
out period has expired (approximately 10 seconds), the local unit
will begin loading all remote units in parallel using a proprietary
protocol. A message similar to the one below will be displayed.
unit is added to a list of units to be loaded. When the response time-
out period has expired (approximately 10 seconds), the local unit
will begin loading all remote units in parallel using a proprietary
protocol. A message similar to the one below will be displayed.
Loading 004096001d45
Loading 004096001d45
If any remote units timeout during the load, they are removed from
the list. Once all units have completed loading, the local unit dis-
plays a count of the successful loads. A message similar to the fol-
lowing will be displayed.
the list. Once all units have completed loading, the local unit dis-
plays a count of the successful loads. A message similar to the fol-
lowing will be displayed.
Completed loading 004096001d45
Completed loading 00409610345f
Loading of 2 Aironet 340 Series Bridges completed