Release Notes for Cisco Aironet 1130AG, 1200, 1230AG, and 1240AG Series Access Points for Cisco IOS Release 12.3(7)JX9
OL-14252-01
Installation Notes
Step 8
Wait until the access point reboots as indicated by all LEDs turning green followed by the Status LED 
blinking green.
Step 9
After the access point reboots, reconfigure the access point using the GUI or the CLI.
Installation Notes
This section contains information you should keep in mind when installing access points.
Installation in Environmental Air Space
This section provides information on installing 1200 series access points in environmental air space, 
such as above suspended ceilings.
Cisco Aironet 1130AG and 1200 Series Access Points provide adequate fire resistance and low 
smoke-producing characteristics suitable for operation in a building's environmental air space, such as 
above suspended ceilings, in accordance with Section 300-22(C) of the National Electrical Code (NEC) 
and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part 1, C22.1.
Caution
The power injector does not provide fire resistance and low smoke-producing characteristics and is not 
intended for use in extremely high or low temperatures or in environmental air spaces such as above 
suspended ceilings.
Note
If you plan to mount a 1200 series access point with a 5-GHz radio in an area subject to environmental 
air space, Cisco recommends that you mount the access point horizontally so that its antennas point 
down. Doing so ensures that the access point complies with regulatory requirements for environmental 
air space with the 5-GHz radio installed. 
Power Considerations
This section describes issues you should consider before applying power to an access point.
Caution
The nominal voltage for 1200 series access points is 48 VDC, and the access point is operational up to 
60 VDC. Voltage higher than 60 VDC can damage the equipment.
Caution
Cisco Aironet power injectors are designed for use with Cisco Aironet access points and bridges only. 
Do not use the power injector with any other Ethernet-ready device. Using the power injector with other 
Ethernet-ready devices can damage the equipment.