Cisco Cisco Aironet 3500p Access Point 설치 가이드

다운로드
페이지 30
26
 
Australia
This system has been evaluated for RF exposure for Humans as referenced in the Australian Radiation 
Protection standard and has been evaluated to the ICNIRP (International Commission on 
Non-Ionizing Radiation Protection) limits. The minimum separation distance from the antenna to 
general bystander is 20cm (7.9 inches). Installations utilizing antennas with gain greater than 10 dBi 
will assure a separation distance of at least 30 cm.
Declaration of Conformity Statements
All the Declaration of Conformity statements related to this product can be found at the following 
location: 
10  
Configuring DHCP Option 43 and DHCP Option 60
This section contains a DHCP Option 43 configuration example on a Windows 2003 Enterprise DHCP 
server for use with Cisco Aironet lightweight access points. For other DHCP server implementations, 
consult product documentation for configuring DHCP Option 43. In Option 43, you should use the 
IP address of the controller management interface.
Note
DHCP Option 43 is limited to one access point type per DHCP pool. You must configure a 
separate DHCP pool for each access point type.
The 3502P access point uses the type-length-value (TLV) format for DHCP Option 43. DHCP servers 
must be programmed to return the option based on the access point’s DHCP Vendor Class Identifier 
(VCI) string (DHCP Option 60). The VCI string for the 3502P access point is:
Cisco AP c3502
The format of the TLV block is listed below: 
Type: 0xf1 (decimal 241) 
Length: Number of controller IP addresses * 4 
Value: List of WLC management interfaces 
To configure DHCP Option 43 in the embedded Cisco IOS DHCP server, follow these steps: 
Step 1
Enter configuration mode at the Cisco IOS CLI. 
Step 2
Create the DHCP pool, including the necessary parameters such as default router and name 
server. A DHCP scope example is as follows: 
ip dhcp pool
 <pool name>