Cisco Cisco Aironet 350 Wireless Bridge 문제 해결 가이드

다운로드
페이지 10
When the transfer is complete, the system displays the updated contents of all memory types.
Note: In this output, the system displays the newly upgraded firmware version 12.05 (Highlighted in
Bold).
Memory Bank   total      used      left
  DRAM      16742624   1501612  15241012
  Config      524288       292    523996
  FLASH      7602176         0   7602176
Memory Bank:File                     address      size   encoding type  flags
  a) DRAM  :EnterpriseAP Sys 12.05   00008720   1225476  gzip     Exec  0901
  b) DRAM  :EnterpriseAP Web 12.05   00133A24    149300  .tar.gz  Web   0000
  c) DRAM  :Inflate Ver. c14o        00158158      7496  gzip     Dcdr  0900
  d) DRAM  :350 Series FW 5.20.47    00159EA0     59292  .tar.gz  Data  0000
  e) DRAM  :AIR−CB20A FW 5.20.47     0016863C     60048  .tar.gz  Data  0000
  f) Config:AP Installation Key      FF820000        80  none     Key   0000
  g) Config:AWC_ConfigDB             FF820050       212  AiroDB1  Data  0000
Set the console baud rate back to 9600 bps to reduce the possibility of errors or problems after the file
transfer is complete.
Press n to select the console at the main menu.
c −− Copy file
f −− File dir
l −− downLoad file into DRAM
u −− Upload file
p −− xfer Protocol
n −− coNsole
r −− Run
s −− System info.
!−−− FORMAT memory bank.
a. 
Press b to change the baud rate.
b −− Baud (all N/8/1)
e −− Echo test (<esc> stops)
o −− Output test (any key stops)
l −− LED test
b. 
Press b to set the baud rate back to 9600 bps.
c. 
14.