Cisco Cisco ASR 5700
HSGW Service Configuration Mode Commands
▀ bind address
▄ Command Line Interface Reference, StarOS Release 17
6256
bind address
Binds the service to a logical IP interface serving as the A10 interface and specifies the maximum number of subscribers
that can access this service over the configured interface.
that can access this service over the configured interface.
Product
HSGW
Privilege
Administrator
Mode
Exec > Global Configuration > Context Configuration > HSGW Service Configuration
configure > context context_name > hsgw-service service_name
Entering the above command sequence results in the following prompt:
[context_name]host_name(config-hsgw-service)#
Syntax
bind address ip_address [ max-subscribers num ]
no bind address
no
Removes the interface binding from this service.
address ip_address
Specifies the IP address of the A10/A11 interface in IPv4 dotted-decimal notation.
max-subscribers num
Specifies the maximum number of subscribers that can access this service on this interface as an integer from
0 through 2500000. Default: 2500000
0 through 2500000. Default: 2500000
Important:
The maximum number of subscribers supported is dependant on the license key installed and the
number of active PSCs in the system. A fully loaded system with 13 active PSCs can support 3,000,000 total
subscribers. Refer to the license key command and the Usage section (below) for additional information.
subscribers. Refer to the license key command and the Usage section (below) for additional information.
Usage
Associate the HSGW service to a specific logical IP address. The logical IP address or interface takes on the
characteristics of an A10/A11 interface that provides the session connectivity to/from an eAN/PCF. Only one
interface can be bound to a service. The interface should be configured prior to issuing this command.
This command also sets a limit as to the number of simultaneous subscribers sessions that can be facilitated
by the service/interface at any given time.
When configuring the
characteristics of an A10/A11 interface that provides the session connectivity to/from an eAN/PCF. Only one
interface can be bound to a service. The interface should be configured prior to issuing this command.
This command also sets a limit as to the number of simultaneous subscribers sessions that can be facilitated
by the service/interface at any given time.
When configuring the
max-subscribers
option, be sure to consider the following:
The total number of A10/A11 interfaces you will configure
The total number of subscriber sessions that all of the configured interfaces may handle during peak
busy hours