Cisco Cisco Aironet 1260 Access Point

다운로드
페이지 512
 
4-6
Cisco IOS Software Configuration Guide for Cisco Aironet Access Points
OL-30644-01
Chapter 4      Configuring the Access Point for the First Time 
Connecting to the 1040, 1140, 1240, 1250, 1260, and 2600 Series Access Points Locally
Connecting to the 1040, 1140, 1240, 1250, 1260, and 2600 Series 
Access Points Locally
If you need to configure the access point locally (without connecting the access point to a wired LAN), 
you can connect a PC to its console port using a DB-9 to RJ-45 serial cable. Follow these steps to open 
the CLI by connecting to the access point console port:
Step 1
Connect a nine-pin, female DB-9 to RJ-45 serial cable to the RJ-45 serial port on the access point and 
to the COM port on a computer. The Cisco part number for the DB-9 to RJ-45 serial cable is 
AIR-CONCAB1200. Browse to 
 to order a serial cable.
Step 2
Set up a terminal emulator to communicate with the access point. Use the following settings for the 
terminal emulator connection: 9600 baud, 8 data bits, no parity, 1 stop bit, and no flow control.
Note
If xon/xoff flow control does not work, use no flow control. 
Step 3
When connected, press enter or type en to access the command prompt. Pressing enter takes you to the 
user exec mode. Entering en prompts you for a password, then takes you to the privileged exec mode. 
The default password is Cisco and is case-sensitive.
Note
When your configuration changes are completed, you must remove the serial cable from the 
access point.
Connecting to the 1300 Series Access Point/Bridge Locally
If you need to configure the access point/bridge locally (without connecting the access point/bridge to a 
wired LAN), you can connect a PC to the Ethernet port on the long-reach power injector using a Category 
5 Ethernet cable. You can use a local connection to the power injector Ethernet port the same as you 
would use a serial port connection.
Note
You do not need a special crossover cable to connect your PC to the power injector; you can use either 
a straight-through cable or a crossover cable.
Follow these steps to connect to the bridge locally:
Step 1
Make sure that the PC you intend to use is configured to obtain an IP address automatically, or manually 
assign it an IP address within the same subnet as the access point/bridge IP address. For example, if you 
assigned the access point/bridge an IP address of 10.0.0.1, assign the PC an IP address of 10.0.0.20.
Step 2
With the power cable disconnected from the power injector, connect your PC to the power injector using 
a Category 5 Ethernet cable. You can use either a crossover cable or a straight-through cable.