Cisco Cisco D9824 Advanced Multi Decryption Receiver 설치 가이드

다운로드
페이지 388
 
 
 
Configuring System Settings 
 
OL-29015-01 
239 
 
5  The Alarm Setup area displays a list of the alarm/fault messages. For more 
information on alarm messages, refer to D9824 Alarm Messages (on page 264).  
6  From the Enable/Disable drop-down list, choose Yes to report the alarm 
message. Choose No to disable the alarm and the Relay and Trap settings are 
ignored. 
Note: Enable/Disable must be set to Yes for the Relay and Trap settings to be 
functional. 
7  If current alarm is enabled, from the Trap drop-down list, choose Yes to send the 
SNMP trap message when the alarm is set or cleared. 
Note: No is a read only value that indicates the setting is Yes, but is currently 
being suppressed because the alarm is disabled (Enb is set to No). 
8  If current alarm is enabled, from the Relay drop-down list, choose Yes to trigger 
the rear panel alarm when the alarm is set or cleared. 
Note: No is a read only value that indicates the setting is Yes, but is currently 
being suppressed because the alarm is disabled (Enb is set to No). 
9  Click Apply
 
To Set Up Warnings 
1  
From the Alarm Setup page, click the Warning Setup link at the bottom left hand 
corner of the page. The Warning Setup page is displayed. 
 
2  Check the Enable Alarm/Warning Front Panel Reminder check box for the 
warning to flash on the LCD display for a two-second interval every 10 seconds. 
The warning will continue to flash periodically until it is either cleared or the 
Enable Alarm/Warning Front Panel Reminder is de-selected. 
3  The Warning Setup area displays a list of the warning messages. For more 
information on warning messages, refer to D9824 Alarm Messages (on page 264).