Chapter 3 Installation
78
OL-29643-02
but do not remove them. Then lift the housing into proper position on the strand.
4 Slip the clamps over the strand and finger-tighten the clamp bolts. This allows
additional side-to-side movement of the housing as needed.
5 Move the housing as needed to install the coaxial cable and connectors. See the
illustrations below for an example
Powered from Left
Powered from Left
Powered from Right
Note: If supplying power to the node through a main output port, a power
inserter must be installed to inject the AC voltage onto the RF signal.
6 Use a torque wrench and a 1/2-inch socket to tighten the strand clamp bolts
from 5 ft-lb to 8 ft-lbs (6.8 to 10.8 Nm).
Note: A slight tilt of the face of the housing is normal. Cable tension will cause
the housing to hang more closely to vertical.
Note: A slight tilt of the face of the housing is normal. Cable tension will cause
the housing to hang more closely to vertical.
7 Connect the coaxial cable to the pin connector according to the pin connector
manufacturer’s specifications.
8 Continue to Fiber Optic Cable Installation (on page 81) and RF Cable
Installation (on page 88).