Chapter 4    Setup and Operation 
 
 
 
118 
OL-29643-02 
 
 
1x2 and 1x4 Redundant Forward Configuration Modules with Forward 
RF Injection 
A primary receiver (RCVR 1) and a redundant receiver (RCVR 2) feed all RF output 
ports. The FLI Module routes an RF signal from an external source to the Forward 
Configuration Module which is then coupled with the input from RCVR 1/2. 
The Status Monitor/Local Control Module automatically switches from primary 
receiver to redundant receiver when it senses a loss of optical input to the primary 
receiver. Once optical input is restored, the system automatically switches back to 
the primary receiver. 
Install the primary receiver in RCVR 1 and the redundant receiver in RCVR 2. Install 
the FLI module in the RCVR 4 position. 
 
2-way forward segmentable node 
4-way forward segmentable node 
The following diagram illustrates forward path signal flow in this configuration 
module.