Cisco Headend System Release 2.5 관리 매뉴얼
Recommendations to Improve Your Data Carousel Rate
4024836 Rev D
67
VPI / VCI Pairing
Note: This discussion of VPI/VCI pairing pertains only to sites that use a BFS BIG
Note: This discussion of VPI/VCI pairing pertains only to sites that use a BFS BIG
and does not pertain to sites that use an ASI/HMUX card. The Direct ASI
implementation does not use ATM.
We recommend that you map at least 20 VPI/VCI pairs in your Asynchronous
We recommend that you map at least 20 VPI/VCI pairs in your Asynchronous
Transfer Mode (ATM) switch for inband data when initially configuring the system.
The DNCS port on the ATM switch uses VPI/VCI permanent virtual circuits (PVCs)
0/256 through 0/275. These PVCs must be mapped to VPI/VCI pairs x/256 through
x/275 respectively, (where x represents any available VPI) on the Broadband
Integrated Gateway (BIG) port of the ATM switch. There is one VPI/VCI PVC for
each inband data carousel for up to 20 inband carousels.
If you plan to support more than 20 inband data carousels, you need additional
If you plan to support more than 20 inband data carousels, you need additional
PVCs on the ATM switch. Begin configuring your additional PVCs at 0/276.
The BIG ATM module has no awareness of the VPI. Hence, the ATM switch can map
The BIG ATM module has no awareness of the VPI. Hence, the ATM switch can map
the incoming DNCS PVCs to any VPI on the outgoing BIG PVCs. For simplicity, we
recommend that you use VPI of 0.
Change the Data Carousel Rates for an SR 2.5/3.5 and Later System
The instructions in this section guide you through the steps of editing the data
carousel rates (and related fields) on a system that supports SR 2.5/3.5/4.0 or later
system software.
Note: To edit the data carousel rates on a DBDS using a prior release, refer to
Note: To edit the data carousel rates on a DBDS using a prior release, refer to
Recommendations for Data Carousel Rate Management Technical Bulletin (part number
716377).
Changing the Data Carousel Rates for the bootloader
Follow these instructions to change the data carousel rates.
1 From the DNCS Administrative Console, select the Application Interface
Follow these instructions to change the data carousel rates.
1 From the DNCS Administrative Console, select the Application Interface
Modules tab.