Cisco Model 6944 and 6940 Node bdr Dig Rev 2 1 Mux System for Prisma II 데이터 시트

다운로드
페이지 7
Prisma II bdr Digital Reverse 4:1 Multiplexing System 
 
4
 
 
Module Specifications 
 
4:1 Transmit Processor 
Units 
 
Notes 
RF Input Level Requirements 
dBmV/Hz 
See Link Performance Section 
 
RF Input Return Loss 
dB 
18 
 
Input RF Variable Attenuation Range 
dB 
0 to 10 
 
Data Output to Laser Module 
Gbps 
2.5 
 
Input Test Point 
dB 
-20 (
±
 1.0) 
Power Consumption (maximum) 
18.5 
 
 
Laser Module 
Units 
 
Notes 
Data Input from 4:1 Transmit Processor 
Gbps 
2.5  
 
 
 
 
 
Optical Wavelength 
nm 
1550 ITU grid 100 GHz spacing 
1550 non-ITU 
1310 nm 
 
 
 
 
 
Optical Output Power (modulated) 
dBm 
0 (1550 non-ITU & 1310) 
0 or 7 (1550 ITU) 
 
 
 
 
 
Optical Interface 
 
SC/APC Connector 
 
Power Consumption (maximum) 
W
 
8 (1550 nm), 6.5 (1310 nm) 
 
 
4:1 Receive Processor 
Units 
 
Notes 
Data Input from Receiver Module 
Gbps 
2.5 
 
RF Output Level 
dBmV/Hz 
See Link Performance Section 
 
RF Output Return Loss 
dB 
18 
 
Output RF Variable Attenuation Range 
dB 
0 to 10 
 
RF Output Test Point 
dB 
-20 (
±
 0.5) 
Power Consumption (maximum) 
16.5 
 
 
Receiver Module 
Units 
 
Notes 
Optical Input Power Range: (SR Module) 
Optical Input Power Range: (ER Module) 
dBm 
dBm 
-5 to -22 
-10 to -29 

Data Output to Receive Processor 
Gbps 
2.5 
 
Optical Interface 
 
SC/APC connector 
 
Power Consumption (maximum) 
 
 
 
 
Mechanical 
Units 
 
Notes 
Operating Temperature Range (ambient) 
°
°
-40 to +65 
-40 to +149 
Physical Dimensions  (any Processor with 2 
Receiver or 2 Laser Modules) 
    Depth 
 
 
in. 
cm 
 
 
9.8 
24.9 
 
    Width 
in. 
cm 
2.1 
5.3 
 
    Height 
in. 
cm 
7.6 
19.3 
 
    Weight 
lb 
kg 
5.0 
2.3 
 
Notes:  
1.  Test point level is referenced to RF input 
2.  Test point level is referenced to RF output 
3.  System designs should consider the effects of wavelength dispersion in long fiber lengths. This can result in up to 2 dB 
loss of Rx sensitivity over a 100 km distance. 
4.  Recommended for use only in non-condensing environments.