Cisco Cisco StadiumVision Mobile Streamer 관리 매뉴얼

다운로드
페이지 19
 
 
© 2010 Cisco Systems, Inc. All rights reserved. This document is Cisco Internal Information.  Page 15 of 19 
Field 
Required 
Description 
Possible Values 
Old Suite Name 
No 
The name of an existing luxury suite or 
other local control area.  
This field is required if the operation type 
is Update and the Suite Name is being 
changed. 
Must match an existing suite name. 
Suite DMP Logical 
ID 
Yes, if device 
is associated 
with a local 
control area 
For a given suite, the logical number for 
each device. This determines the order in 
which the TV labels are displayed on the 
IP phone.  For example, in a given suite, 
Main may be 1, Bar may be 2, outside 
may be 3. 
A numeric value 1 through x, where 
is the total number of TVs/DMPs 
in the suite. 
TV Name 
No 
The label shown on the TV when the 
banner is brought up on the TV. This is 
also the name displayed on the IP phone 
identify the TV. For example, the label 
may be a description of the TV's location 
in the suite, like Main or Bar. 
Alphanumeric text. Because this 
name (or label) is displayed on the 
IP Phone, the name should be 
limited to 12 characters or less. 
Due to the space allotted for display 
labels on the IP Phone interface, 
more than 12 characters may have 
undesirable results. 
Suite Controller IP 
Yes, if device 
is associated 
with a local 
control area 
(not required if 
Suite Control 
Type is 
Infrared) 
The IP address of the IP phone or third 
party device that will be controlling this 
suite. 
Must be unique. Must be a valid 
IPv4 address (e.g. 0.0.0.256 is not 
permitted). StadiumVision Director 
does not validate the address or 
check for duplicates; it only verifies 
that the IP Address is in the correct 
format. 
Suite Controller 
MAC 
No 
The MAC address of the IP phone or third 
party device that will be controlling this 
suite. 
May be in the form 
AA:BB:CC:DD:EE:FF or 
aabb.ccdd.eeff or aabbccddeeff 
The only permitted characters are 
0-F and colon, dash, period as 
shown above and letters are not 
case sensitive. 
Suite Controller 
Name 
Yes, if device 
is associated 
with a local 
control area 
(not required if 
Suite Control 
Type is 
Infrared) 
The human readable name of the local 
control device.  
Should only use A-Z a-z 0-9 space 
_ - 
Invalid Characters % * , : ? = / \ " ' [ 
] ( ) + 
Not to exceed 200 characters and 
spaces.  
 
Old Suite Controller 
Name  
No 
The existing human readable name of the 
local control device.  
This field is required if the operation type 
is Update and the Suite Controller Name 
is being changed. 
Must match an existing device 
name. 
External Suite ID 
No 
The suite ID used to identify this suite in 
the Point of Sale system.  
The external suite ID must match 
value configured in the Point of 
Sale system.  
External Suite 
Name  
No 
The suite name used to identify this suite 
in the Point of Sale system.  
The external suite name (if 
configured)  must match value 
configured in the Point of Sale 
system.