751173 Rev D 
Upgrading a GainMaker Line Extender 
Installing the Upgrade Kit,
 Continued 
Removing the Power Cable Harness 
Follow these steps to remove the existing power cable harness assembly from the 
line extender housing. 
 
1. 
Unplug the 10-pin keyed connectors of the power cable harness from the 
amplifier module and the power supply module.  
 
2. 
Remove the power cable harness from the white plastic retainer clip. 
3. 
Unsnap the cable guide from the holes in the amplifier module cover. 
4. 
Using a Phillips-head torque screwdriver, remove the cable guide screws 
from the line extender housing lid and set the screws aside for later use. 
5. 