Cisco Prisma HDRx Reverse Optical Receiver Platform & Power Supply System 데이터 시트
Prisma HDRx Reverse Optical Receiver Platform
4
Power Supply Specifications, continued
2RU Power Supply
General Performance
Units
AC
-48 V DC
Notes
Input voltage requirements
V
90 to 265
(50/60 Hz)
-40 to -75
1
Output voltage/current
V DC/A
+8 / 25
+8 / 25
Power consumption (fan tray #744332)
W
Typ. 35, max 72
Efficiency (minimum)
%
> 68
> 68
Line regulation
%
≥ 0.5
≥ 0.5
Redundancy switch time
ms
0
0
Environmental
Operating temperature range
Operating temperature range
°F
°C
-40 to +149
-40 to +65
2
Humidity range
%
0 to 95
3
Mechanical
Physical dimensions, total chassis
Physical dimensions, total chassis
in.
cm
17.2 W x 3.7 H x 9.8 D
43.7 W x 9.4 H x 24.9 D
Physical dimensions, one supply
in.
cm
8.5 W x 1.65 H x 8.5 D
21.6 W x 4.2 H x 21.6 D
Weight lb
kg
6.0
2.7
2.7
Notes:
1.
One power supply unit including 6 ft. (1.8 m) AC power cord with AC unit
2.
Air temperature measured at the air inlet of the chassis
3.
Recommended for use only in non-condensing environments
2RU Power Supply Application
Only one (1) power supply unit is needed to power up to two HDRx rack units. To provide redundant operation
two (2) power supply units are needed. The power cables are connected on the rear of the chassis. One cable is
included with the chassis. An extra cable must be ordered separately. See ordering information.
Same or different power sources may be applied. One of the power supplies may be an AC powered unit and the
other power supply may be a DC powered unit. In the event of AC power failure the DC powered unit will then act
as backup.
two (2) power supply units are needed. The power cables are connected on the rear of the chassis. One cable is
included with the chassis. An extra cable must be ordered separately. See ordering information.
Same or different power sources may be applied. One of the power supplies may be an AC powered unit and the
other power supply may be a DC powered unit. In the event of AC power failure the DC powered unit will then act
as backup.
HDRx chassis
1
HDRx chassis
2
Extra Power Cable
must be ordered
separately
Fan Tray
Power Supply Units