Cisco Prisma HDRx Reverse Optical Receiver Platform & Power Supply System 데이터 시트

다운로드
페이지 5
Prisma HDRx Reverse Optical Receiver Platform 
 
4
 
 
Power Supply Specifications, continued 
 
2RU Power Supply 
General Performance 
Units 
AC 
-48 V DC 
Notes 
Input voltage requirements 
90 to 265 
(50/60 Hz) 
-40 to -75 
Output voltage/current 
V DC/A 
+8 / 25 
+8 / 25 
 
Power consumption (fan tray #744332) 
Typ. 35, max 72 
 
Efficiency (minimum) 
> 68 
> 68 
 
Line regulation 
≥ 0.5 
≥ 0.5 
 
Redundancy switch time 
ms 
0  
Environmental 
Operating temperature range 
°F 
°C 
-40 to +149 
-40 to +65 
Humidity range 
0 to 95  
Mechanical 
Physical dimensions, total chassis 
in. 
cm 
17.2 W x 3.7 H x 9.8 D 
43.7 W x 9.4 H x 24.9 D 
 
Physical dimensions, one supply 
in. 
cm 
8.5 W x 1.65 H x 8.5 D 
21.6 W x 4.2 H x 21.6 D 
 
Weight lb 
kg 
6.0 
2.7 
 
Notes: 
1. 
One power supply unit including 6 ft. (1.8 m) AC power cord with AC unit 
2. 
Air temperature measured at the air inlet of the chassis 
3. 
Recommended for use only in non-condensing environments 
 
2RU Power Supply Application 
Only one (1) power supply unit is needed to power up to two HDRx rack units.  To provide redundant operation 
two (2) power supply units are needed.  The power cables are connected on the rear of the chassis.  One cable is 
included with the chassis.  An extra cable must be ordered separately.  See ordering information. 
 
Same or different power sources may be applied.  One of the power supplies may be an AC powered unit and the 
other power supply may be a DC powered unit.  In the event of AC power failure the DC powered unit will then act 
as backup. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
HDRx chassis
1
HDRx chassis
2
Extra Power Cable
must be ordered
separately
Fan Tray
Power Supply Units