Cisco Compact Outdoor Amplifier Model 93412 데이터 시트
Compact Mini Amplifier 93191
Specifications
General Performance
Units
93191-x28
93191-x36
Notes
Forward path
MHz
40 - 862
1
Reverse path
MHz
5 - 80
1
Gain
dB
28
36
Attenuator, plug-in
dB
0 - 18 (in 1 dB steps)
Equalizer, plug-in
dB
0 - 18 (in 1 dB steps)
Output tilt
dB
0 / 3 / 6 / 9
Number of outputs
2
2
Return loss, 5 - 40 MHz
dB
20
Return loss, 40 - 862 MHz
dB
20 red. 1.5 / octave
Passive reverse loss, with 74069
dB
1.8
Output level: CTB
³ 60 dB, typical
dBµV 112.0
3
Output level: CSO
³ 60 dB, typical
dBµV 112.0
116.5 3
Noise figure
dB
³ 8.5
³ 7.5
Electrical
Remote (coax line)
V AC
24 - 65
Power consumption, remote powered
W
14.5
4
Current consumption, 24 V AC, fully loaded
mA
< 845
Current consumption, 40 V AC, fully loaded
mA
< 530
Current consumption, 60 V AC, fully loaded
mA
< 390
Max. current, input/output
A AC
3
Hum modulation, at max. current
dB
< - 65
Over-voltage protection
ms
2 kV, 1.2 / 50
Environmental
Operating temperature range
°C
-20 to + 55
Enclosure category
IP 64
Mechanical
Connectors, input
PG11 (5/8”)
Connectors, output and test point
F
Housing dimensions excl. mounting fittings
mm
185 W x 145 H x 95 D
Emission, EN 50083-2
dBpW
< 20
Screening efficiency
dB
> 85
Weight
kg <
2,2
All specifications are measured with 0 dB link 74089 at the filter connectors.
Notes:
1)
Frequency range depends on the diplex filters
2)
With plug-in splitter
3)
CTB/CSO is measured with 6 dB pre-equalizer, EN 50083-3.2.
4)
Exclusive active reverse; for active reverse add 1.5 W