Module Commands 
 
78-4025693-01 Rev D 
43 
 
Argument 
Details 
Description 
Majorlow 
Low Major threshold 
Minorhigh 
High Minor threshold 
Minorlow 
Low Minor threshold 
Nominal 
alarm nominal value 
Rangehi 
upper limit for this threshold 
Rangelo 
lower limit for this threshold 
Type 
alarm type (1, 2, and 7 are adjustable) 
Value 
alarm state 
Control 
 
Index 
control number, starting at 1, in the list of controls 
Label 
name of the control 
Rangehi 
upper limit for this control 
Rangelo 
lower limit for this control 
Rangestep 
smallest increment allowed 
Statenames 
list of symbolic control values 
Type 
control type:  D(igital), F(loat), B(oolean), S(tate) 
Units 
control unit 
Value 
control setting 
Monitor 
 
Index 
monitor number, starting at 1, in the list of 
monitors 
Label 
name of monitor 
Statenames 
list of symbolic values 
Type 
value type:  D(igital), F(loat), B(oolean), S(tate) 
Units 
units of measurement 
Value 
value 
Module 
 
Activerev 
active software image revision for the module 
Bootrev 
current boot image revision for the module 
CLEI 
Common Language Equipment ID code for 
module 
CLLI 
Common Language Locator ID code for module 
Coderev 
code revision 
Datecode 
manufacturing date (encoded) 
Devtype 
numeric type value used for element manager