Cisco Cisco Prisma II EDR Receiver 설치 가이드

다운로드
페이지 106
3-14 
Operation Using the ICIM 
78-713378-01 Rev C 
Monitoring Operating Status Using the ICIM 
Monitored Parameters  
The table below describes the monitored parameters for this module. 
Parameter  
Function 
Operating Range 
InPwr1 
Displays optical input power for Rx 1 
-17.0 dBm to +2.0 dBm  
InPwr2 
Displays optical input power for Rx 2 
-17.0 dBm to +2.0 dBm  
ModTemp 
Displays module temperature. 
-40°C and 65°C  
Mute1 
Mute status for Rx 1 
ON or OFF 
Mute2 
Mute status for Rx 2 
ON or OFF 
Alarm 1 
Alarm for Rx 1 
ON or OFF 
Alarm 2 
Alarm for Rx 2 
ON or OFF 
Enable 1 
Rx 1 Enabled 
ON or OFF 
Enable 2 
Rx 2 Enabled 
ON or OFF 
Master 1 
Rx 1 Master 
ON or OFF 
Master 2 
Rx 2 Master 
ON or OFF 
NomPwr1 
Nominal input power 
-20.0 dbm to 0 dBm 
NomPwr2 
Nominal input power 
-20.0 dbm to 0 dBm 
 
Checking Operating Status  
Using the ICIM, you can check the status of all operating parameters of this module. 
To monitor the module operating parameters, follow these steps. 
1. 
From the MAIN menu, press the 
 
 key to highlight Shelf and Slot fields.  
2. 
Press the 
SEL
 key to address the Shelf number. Then press the 
 
 key or 
the 
 key to scroll to the number of the desired shelf.      
3. 
Press the 
ENTER
 key. The Slot field is highlighted. 
4. 
Press the 
 
 key or the 
 key to scroll to the number of the desired slot.   
5. 
Press the 
ENTER
 key.  The information for the module of interest is now 
displayed on the ICIM menu. 
6. 
When you have reached the desired module’s location, press the 
STAT
 key.  
7. 
Press the 
 
 key or the 
 
 key to scroll through the monitored 
parameters until you find the parameter of interest. 
8. 
Check the status of the desired parameter or select other parameters to 
monitor. When finished, press the 
MAIN
 key to return to the MAIN menu. 
 
Continued on next page