Operation Using the ICIM
78-713378-01 Rev C
Monitoring Operating Status Using the ICIM
Monitored Parameters
The table below describes the monitored parameters for this module.
Parameter
Function
Operating Range
InPwr1
Displays optical input power for Rx 1
-17.0 dBm to +2.0 dBm
InPwr2
Displays optical input power for Rx 2
-17.0 dBm to +2.0 dBm
ModTemp
Displays module temperature.
-40°C and 65°C
Mute1
Mute status for Rx 1
ON or OFF
Mute2
Mute status for Rx 2
ON or OFF
Alarm 1
Alarm for Rx 1
ON or OFF
Alarm 2
Alarm for Rx 2
ON or OFF
Enable 1
Rx 1 Enabled
ON or OFF
Enable 2
Rx 2 Enabled
ON or OFF
Master 1
Rx 1 Master
ON or OFF
Master 2
Rx 2 Master
ON or OFF
NomPwr1
Nominal input power
-20.0 dbm to 0 dBm
NomPwr2
Nominal input power
-20.0 dbm to 0 dBm
Checking Operating Status
Using the ICIM, you can check the status of all operating parameters of this module.
To monitor the module operating parameters, follow these steps.
1.
From the MAIN menu, press the
key to highlight Shelf and Slot fields.
2.
Press the
SEL
key to address the Shelf number. Then press the
key or
the
key to scroll to the number of the desired shelf.
3.
Press the
ENTER
key. The Slot field is highlighted.
4.
Press the
key or the
key to scroll to the number of the desired slot.
5.
Press the
ENTER
key. The information for the module of interest is now
displayed on the ICIM menu.
6.
When you have reached the desired module’s location, press the
STAT
key.
7.
Press the
key or the
key to scroll through the monitored
parameters until you find the parameter of interest.
8.
Check the status of the desired parameter or select other parameters to
monitor. When finished, press the
monitor. When finished, press the
MAIN
key to return to the MAIN menu.
Continued on next page