General Troubleshooting Information, Continued 
 
Alarm 
Possible Cause 
Servicing Instruction 
Low or High 
Optical Output 
Power 
 
Laser failure 
 
Optical connector 
mismatch 
 
Optical connector 
contains dusts or 
contaminants 
 
Check whether the laser 
has been switched on   
 
Check whether the 
optical connector 
matches   
 
Make sure all the mating 
surfaces of the fiber are 
clean 
 
Check whether the 
optical input power is 
between (standard value 
- 4. 0) dBm and (standard 
value + 1. 0) dBm with 
an optical power meter.   
 
If the problem persists, 
contact the manufacturer 
for servicing 
 
CAUTION: 
Do not open the enclosure of this module in any case. Opening the enclosure 
may result in equipment damage, and you may lose the warranty eligibility. 
 
 
 
 
OL-29666-02   
Troubleshooting 