Cisco Cisco OptoStar II Driver Amplifier 설치 가이드

다운로드
페이지 67
Starting up the Module, Continued 
Signal Inspection 
Use a DB meter or spectrum analyzer to measure the RF level to be inputted 
into the module, to ensure the appropriate RF level into the forward driver 
amplifier module. If the input level is out of the range, the module performance 
will be degraded. 
• 
RF input signals are divided into the following three conditions:   
1.  If the RF input signal has only analog signal, the analog signal input 
level is 15 ± 5 dBmV/channel at the broadcast RF input port.   
Recommended input level: the analog signal is 15 dBmV/channel at the 
broadcast RF input port. 
2.  If the RF input signal has both analog signal and digital signal, the 
analog signal input level is 15 ± 5 dBmV/channel at the broadcast RF 
input port; the digital signal input level is 9 ± 5 dBmV/channel at the 
broadcast RF input port; and the digital signal input level is 21 ± 5 
dBmV/channel at the narrowcast RF input port.   
Recommended input level: the analog signal is 15 dBmV/channel at the 
broadcast RF input port; the digital signal input level is 9 
dBmV/channel at the broadcast RF input port; and the digital signal 
input level is 21 dBmV/channel at the narrowcast RF input port. 
 
3.  If the RF input signal has only digital signal, the digital signal input 
level is 15 ± 5 dBmV/channel at the broadcast RF input port.   
Recommended input level: the digital signal is 15 dBmV/channel at the 
broadcast RF input port. 
• 
A DB meter or spectrum analyzer can be used to measure the RF output 
level via the RF test point on the front panel. The RF input level can be 
adjusted if necessary. When the broadcast RF input, the actual value of the 
input level (dB) equals to the measured value +20. 0 ± 1. 0; when the 
narrowcast RF input, the actual value of the input level (dB) equals to the 
measured value +32. 0 ± 1. 0. 
OL-29667-02 
Operation 
3-3