General Troubleshooting Information, Continued 
Troubleshooting 
If the red alarm indicator on the front panel of the module is illuminated, check 
the OptoStar II ICIM display, the OptoStar II console, or the OptoStar II NMS for 
alarm code. See Alarm Code List (on page 3-12) to determine the cause of the 
alarm. See the table below. 
Alarm 
Possible Cause 
Servicing Instruction 
Fan Abnormality   
 
Fan has line fault 
 
Fan is jammed by 
foreign body     
 
Replace the fan, or contact 
the manufacturer for 
servicing 
High Module 
Temperature 
 
High ambient 
temperature leading 
to insufficient heat 
dissipation 
 
Poor chassis 
ventilation 
 
Chassis fan failure 
 
Ensure good ventilation   
 
Put the chassis in a place 
with good ventilation 
 
In case of fan failure, 
replace the fan, or contact 
the manufacturer for 
servicing 
After connection of 
Mini-USB, ICIM 
LCD does not 
show USB 
connection screen   
 
Mini-USB cable failure   
 
Mini-USB port failure   
 
Check if it’s properly 
connected or re-connect it 
 
Replace with other data 
cable 
 
If still no response, 
contact the manufacturer 
for servicing   
After connection of 
RJ-45 cable, the 
Link indicator at 
the top right corner 
of the ICIM screen 
is not lit.   
 
RJ-45 cable failure   
 
RJ-45 port failure   
 
Check if it’s properly 
connected or re-connect it 
 
Replace with other data 
cable 
 
If still no response, 
contact the manufacturer 
for servicing   
 
CAUTION: 
Do not open the enclosure of this module in any case. Opening the enclosure 
may result in equipment damage, and you may lose the warranty eligibility. 
 
 
 
 
4-4 
Troubleshooting 
OL-29660-03