The table below lists the setup parameters of the OptoStar II reverse receiver 
module. 
Setup Parameters  Description 
Factory Default 
Optical Alarm 
Threshold 
Shows/sets optical alarm high 
limit and low limit 
Low limit: - 17.0 dB 
High limit: + 3.0 dB 
Module Alarm 
Enable 
Shows / sets module alarm status 
Alarms of all the four 
modules are enabled 
Test Point 
Shows / sets module test point or 
no test point 
No Test Point 
Alarm ON/OFF 
Shows / sets module alarm status: 
ON/OFF 
Alarm ON/OFF corresponds with 
Module Alarm Enable: for 
example, if only Module 1 and 
Module 2 need to be monitored, 
then select Module 1 and Module 2 
in Module Alarm Enable, and 
Alarm ON/OFF in ON position. 
Alarm status: ON 
Gain Control 
Mode Selection 
for Four Modules 
Shows / sets AGC or MGC gain 
control mode 
AGC mode for all 
four modules (0 dB in 
MGC mode) 
 
 
 
3-22 
 