Cisco Cisco FirePOWER Appliance 7030 릴리즈 노트

다운로드
페이지 45
Version 5.3.0.2
Sourcefire 3D System Release Notes
34
Known Issues
The system requires additional time to reboot appliances running Version 
5.3 or later due to a database check. If errors are found during the database 
check, the reboot requires additional time to repair the database. (135564, 
136439)
In some cases, the system may generate a false positive for the SSH 
preprocessor rule 128:1. (135567)
If you apply an intrusion policy containing a rule with the Extract Original 
Client IP Address HTTP preprocessor option enabled, the system may 
populate intrusion events with incorrect data in the Original Client IP field if 
traffic passes through a dedicated proxy server. (135651)
If the maximum transmission unit (MTU) setting on an 8000 Series 
managed device triggers IP datagram fragmentation, the system may 
experience NMSB connection issues. (135731)
If you schedule a task with Report as the job type, the system does not 
attach the report to the emailed status report. (136026)
If you apply an access control policy to multiple devices, the Defense 
Center displays the task status differently on the Task Status page, the 
Access Control policy page, and the Device Management page of the web 
interface. The status on the Device Management page (Devices > Device 
Management) is correct. (136364, 136614)
In some cases, if you create a custom workflow based on the health events 
table, the Defense Center displays conflicting data in the event viewer. 
(136419)
If you import a custom intrusion rule as an 
.rtf 
file, the system does not 
warn you that the .
rtf 
file type is not supported. (136500)
If you configure a Security Intelligence feed and specify a Feed URL that was 
created on a computer running a Windows operating system, the system 
does not display the correct number of submitted IP addresses in the 
tooltips on the Security Intelligence tab. As a workaround, use 
dos2unix
 
commands to convert the file from Windows encoding to Unix encoding 
and click Update Feeds on the Security Intelligence page. (136557)
If you disable a physical interface, the logical interfaces associated with it 
are disabled but remain green on the Interfaces tab of the appliance editor 
for that managed device. (136560)
If you create a custom table based on the Captured Files table, the system 
generates an error message. The system does not support creating a 
custom table based on the Captured Files table. (136844)
If you register a managed device with a hostname containing more than 40 
characters, device registration fails. (137235)
In some cases, the system does not filter objects in the Object Manager as 
expected if you include any of the following special characters in the filter 
criteria: dollar sign (
$
), caret (
^
), asterisk (
*
), brackets (
[ ]
), vertical bar (
|
), 
forward slash (
\
), period (
.
), and question mark (
?
). (137493)