Cisco Cisco UCS C460 M4 Rack Server 데이터 시트

다운로드
페이지 42
Cisco UCS 6200 Series Fabric Interconnect
TECHNICAL SPECIFICATIONS
41
DC input terminal block
If a replacement DC connector is needed, a Phoenix 
Contact part number PC 5/ 2-STF-7,62, order number 
1975697 or direct equivalent. Connector information is 
available at:
Output holdup time
4 ms
RoHS compliance
Yes
Hot swappable
Yes
Heat dissipation
2497 BTU/hr (732 W)
Table 19  Specifications for the Cisco UCS 6248UP AC Power Supply (UCS-PSU-6248UP-AC=) 
DC Power Supply Properties
Description
Maximum output power
750 W
Input Voltage
90 to 264 VAC
Frequency
50 to 60 Hz
Efficiency
88 to 92% (50 to 100% load)
RoHS compliance
Yes
Hot swappable
Yes
Heat dissipation
2497 BTU/hr (732 W)
Table 20  Specifications for the Cisco UCS 6296 750W Power Supply (N10-PAC2-750W=)  
DC Power Supply Properties
Description
Input Voltage
90 to 264 VAC
Frequency
50 to 60 Hz (nominal 47 to 63 Hz)
Input current
9.2 Amps @ 90 VAC
Maximum Input VA
828 VA @ 90 VAC
Maximum output power per power supply
750 W @ 12 VDC (up to two power supplies)
Maximum inrush current
35 A <sub cycle duration
Table 18  Specifications for the Cisco UCS 6248UP DC Power Supply (UCS-PSU-6248UP-DC=)  (continued)
DC Power Supply Properties
Description