Cisco Cisco UCS C250 M2 Extended-Memory Rack Server 백서
24 © 2016 Cisco and/or its affiliates. All rights reserved.
3. For the storage type, choose
Select Disk/LUN and create a data store using the 185-GB LUN, as shown in Figure 36.
Figure 36. Add Persistent Storage to VMware ESXi Host
4. Put the ESXi host into maintenance mode:
vim-cmd hostsvc/maintenance_mode_enter
5. From the ESXi shell, install the latest ESXi version from the following link, as shown in Figure 37:
.
esxcli software vib update -d /vmfs/volumes/Temp/<filename>.zip
Figure 37. Upgrade VMware ESXi
6. Download the Cisco UCS B200 M4 device drivers image ucs-bxxx-drivers.3.0.2a.iso from the following URL and upgrade
the drivers for the NIC, storage, and other components, as shown in Figure 38:
Command: esxcli software vib install --no-sig-check -v /vmfs/volumes/Temp/<filename>.vib
Figure 38. Upgrade Device Driver
Note: ESX drivers can be updated using ZIP file or VIB file. For Zip use -d flag and for VIB file, use -v flag.
7. Verify the path policy (Figure 39)