Samsung AQV12PSLX 사용자 설명서

다운로드
페이지 42
ENGLISH
27
•   Make sure to drill  only  one 
hole after choosing the 
direction of the pipe.
Fixing the installation plate
The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air 
conditioner.
Optional accessories
Tools required for installation
Insulated  
Assembly Pipe,  
Ø6.35mm (1) 
Insulated Assembly Pipe, 
Ø15.88mm (1) 

24
PE T3 Foam Tube 
Insulation (1)
Vinyl Tapes (2)
Insulated Assembly Pipe, 
Ø9.52mm (1) 

12
Insulated Assembly Pipe, 
Ø12.70mm (1) 

18
Pipe Clamps A (3) Pipe Clamps B (3)
Cement Nails (6) 
M4 x 25 Tapped 
Screws (6)
Drain Hose,  
length 2m (1)
Putty 100g (1)
•  If
   these accessories are supplied, they will be in the accessory box.
General Tools
• Vacuum Pump(Backward 
 prevention) 
• Manifold Gauge 
• Stud Finder 
• Torque Wrench 
• Pipe Cutter 
• Reamer 
•  Pipe Bender 
•  Spirit Level 
• Screw Driver 
• Spanner 
• Drill 
•  L Wrench 
• Measuring Tape
Tools for test operations
• Thermometer
Meter 
the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable, 
pipe and hose pass to connect the indoor unit to the outdoor unit. 
When facing the wall, the pipe and cable can be connected from the:
•  
 
Right (A)
  •  
 
Left (B)
   
 
Underside_right (C)
  •
 
 
Rear_right or left (D)
B
A
D
C
D
 Direction of pipe
1.  Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter 
of 65mm so that it slants slightly downwards.
If using a multi system, refer to the manual supplied with the outdoor unit.
74
47
74
Pipe hole 
(Ø65mm)

18/24
•  Resistance
•  Electroscope
120
72
68
72
(Unit : mm)
(Unit : mm)

12
Pipe hole
(Ø65mm)
Drain Plug (1)
Rubber Legs (4)