Providing Information for User
Pump Down Procedure (When Removing The Product)
After finishing the installation of the air conditioner, explain the following to
the user:
How to start and stop the air conditioner
How to select the modes and functions
How to adjust the temperature and fan speed
How to adjust the airflow direction
How to set the timers
How to clean and replace the filters
1.
Turn on the air conditioner and select Cool mode to run the compressor 
for 3 minutes. 
2.
Release the valve caps on High and Low pressure side. 
3.
Use L wrench to close the valve on the high pressure side. 
4.
Approximately 2 minutes after, close the valve on the low pressure side. 
5.
Stop operation of the air conditioner. 
6.
Disconnect the pipes.
•   When you complete the installation successfully, hand over this manual to the user for storage in a handy and safe 