Pump Down Procedure (When Removing The Product)
After finishing the installation of the air conditioner, explain the following to
the user:
1 How to start and stop the air conditioner
2 How to select the modes and functions
3 How to adjust the temperature and fan speed
4 How to adjust the airflow direction
5 How to set the timers
6 How to clean and replace the filters
1.
Turn on the air conditioner and select Cool mode to run the compressor
for 3 minutes.
2.
Release the valve caps on High and Low pressure side.
3.
Use L wrench to close the valve on the high pressure side.
4.
Approximately 2 minutes after, close the valve on the low pressure side.
5.
Stop operation of the air conditioner.
6.
Disconnect the pipes.
• When you complete the installation successfully, hand over this manual to the user for storage in a handy and safe