Samsung ASV12PSBAN 사용자 설명서

다운로드
페이지 45
29
ENGLISH
•   Make sure to drill only one
hole after choosing the
direction of the pipe.
Fixing the installation plate
The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air
conditioner.
Optional accessories
Tools required for installation
Insulated
Assembly Pipe,
Ø6.35mm (1)
Insulated Assembly
Pipe, Ø9.52mm (1)

09/12
Insulated Assembly Pipe,
Ø12.70mm (1)

18
Insulated Assembly Pipe,
Ø15.88mm (1)

24
PE T3 Foam Tube
Insulation (1)
Vinyl Tapes (2)
Drain Plug (1)
AQV
Rubber Legs (4)
Pipe Clamps A (3) Pipe Clamps B (3)
Cement Nails (6)
M4 x 25 Tapped
Screws (6)
Drain Hose,
length 2m (1)
Putty 100g (1)
•  If these accessories are supplied, they will be in the accessory box.
General Tools
• Vacuum Pump(Backward flowing prevention)
• Manifold Gauge
• Stud Finder
• Torque Wrench
• Pipe Cutter
• Reamer
• Pipe Bender
• Spirit Level
• Screw Driver
• Spanner
• Drill
• L Wrench
• Measuring Tape
Tools for test operations
• Thermometer
• Resistance Meter  • Electroscope
You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing
the installation plate to a wall or a window frame, you must determine the position of the 65mm hole through which the cable,
pipe and hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
B
A
D
C
D
Direction of pipe
1.  Determine the position of the pipe and drain hose hole as seen in the picture and drill the hole with an inner diameter 
of 65mm so that it slants slightly downwards.
B
A
D
C
Pipe hole
(Ø65mm)
(Unit : mm)
Model
A
B
C
D

09/12
27 120 68
27

18/24
34 140 68
34
 • Right (A)
 • Left (B)
 • Underside_right (C)
 • Rear_right or left (D)
Brazil_AQV&ASV09P@_IBIM_32441A_E.indd   29