Fixing the indoor unit in place
Insulation
Pipes
Perform the following work on the area where gas leak test was done priorly.
After checking for gas leaks in the system, insulate the pipe, hose and cables.  
Then place the indoor unit on the installation plate.
1.  To avoid condensation problems, wrap foam insulation (as shown in the figure) on 
a part without insulation on the end of the pipes.
2.  Wind the pipe, assembly cable and drain hose with vinyl tape. 
3.  Place the bundle (the pipe, assembly cable and drain hose) in the lower part 
of the indoor unit carefully so it does not project from the rear of the indoor 
unit.
4.  Hook the indoor unit to the installation plate and move the unit to the right 
and left until it is securely in place.
5.  Wrap the rest of the pipe with vinyl tape.
6.  Attach the pipe to the wall using clamps (optional).
Installation 
plate
Connecting wires
Connecting 
pipes
Vinyl tape
Drain hose
•   Make sure pipe does not move when you install the indoor unit on
an installation plate.
'X' mm
Rubber leg
'Y
' m
m
Install the outdoor unit in level on a stable base to avoid the generation of noise and 
vibration, especially when installing the unit close to a neighbor. 
If you install the outdoor unit in a place exposed to strong winds or at a height, fix it to an 
appropriate support (wall or ground).
1.  Place the outdoor unit as indicated on the top of the unit to let the discharged air 
out properly.  
2.  Fix the outdoor unit in level to an appropriate support using anchor bolts.  
3.  If the outdoor unit is exposed to strong winds, install shield plates around the 
outdoor unit so that the fan can operate correctly.
•   Ensure the wall will be able to suspend the weight of rack and
outdoor unit;
•   Install the rack close to the column as much as possible;
•   Install proper grommet in order to reduce noise and residual
vibration transferred by outdoor unit towards wall.
Outdoor unit installed on the wall by rack
Soft rubber designed to cut off 
vibration from rack to wall.  
(not supplied with product)
Designed to cut off residual vibration 
from outdoor unit to rack.  
(not supplied with product)
•  Secure the rubber leg to prevent the generation of noise and vibration.
Model
X
Y

09/12 457
254

18
538
290

24
543
319
Fixing the outdoor unit in place